SERIES 35
|
SERIES A60
|
|
Operating Temperature Range
|
The heating time shown on each fitting is correct for all ambient temperature
conditions within the range - 5deg to +40deg C.
|
Same as Series 35
|
|
Input Voltage
|
240V ac @ 50Hz (Range 195V to 290V ac)
Note:
Input voltage waveform should not exceed a distortion level of more than 20%.
|
Same as Series 35
|
|
Input Voltage Protection
|
Automatic shut-down prevents damage due to high generator power surges.
|
Same as Series 35
|
|
Output Voltage
|
395V RMS ac +- 0.5V
|
Same as Series 35
|
|
Maximum Output Current
|
60 Amps.
|
Same as Series 35
|
|
Fusion Cycletimer
|
Accurate to +- 0.1%
|
Same as Series 35
|
|
Operating Mode
|
Automatic recognition of either manual or automatic fittings determine
operating mode. The control box and output lead
|
Plasson Fusamatic Auto Recognition System only.
|
|
Manual Mode
|
Manual selection of fusion times from 1 to 999 seconds.
|
Not available.
|
|
Automatic Mode
|
Recognition of all Plasson-Fusamatic auto fittings.
|
Same as Series 35
|
|
Fitting Fault
|
Fitting power profile monitored during the heating cycle. The heating cycle
is aborted if the current exceeds 15% of the previously sampled value.
|
Same as Series 35
|
|
Database
|
Provides individual control box identification. Real time clock gives date
and time of each joint. Fitting power profile; periodic sampling of fitting
current and voltage is stored in database. Data storage for last 250 joints
with operator identification code.
|
Not available.
|
|
Control Box Design
|
In accordance with BS 5420 IP44 with seals to prevent ingress of water.
|
Same as Series 35
|
|
Communication Link
|
Standard RS232 format. Baud rate 1200.
|
Not available.
|
|
Weight
|
Control Box in frame and input cable - 35kg.
|
28kg with cables
|
|
Minimum Generator Size
|
2.8 KVA
|
Same as Series 35
|